|Table of Contents|

Energy Consumption and Operating Temperature of Residential Building by Using Radiant Heating(PDF)

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

Issue:
2002年02期
Page:
78-83
Research Field:
Publishing date:

Info

Title:
Energy Consumption and Operating Temperature of Residential Building by Using Radiant Heating
Author(s):
Wang Zijie
College of Power Engineering,Nanjing Normal Hmversity, 210042, Nanjing, PRC
Keywords:
r adiant heat ing residential building oper ating temperatur e building ener gy consumption energ y efficiency
PACS:
TU111.19
DOI:
-
Abstract:
The air temperatur e, inner surface temperature and heating equipment energy consumptio n in w inter season were measur ed for an apartment equipped with radiant heating system. Based on the measur ed results, the average radiant temperature and operating temperature of different rooms with different outside walls w ere calculated and compared. The results show t hat the oper at ing temperature of rooms w ith tw o sides of outside w alls is more than 1℃ higher than that with one side of outside wall. The range of the energy consumptions of the heating system varies from 7. 3 kWh/ m2 to 52 kWh/ m2 for a heating season, depending on the equipment oper ating models and room design temperatures.

References:

[ 1] 王子介. 地板供暖及其发展动向[ J] . 暖通空调, 1999, 6: 35~ 38.
[ 2] 王子介. 地板辐射供冷及地热空气源热泵可行性研究分析[ C] . 全国热泵和空调技术交流会论文集, 2001. 10: 258~ 265.
[ 3] 张建忠, 龚延风. 空气源热泵冷热水机组在南京的应用[ J] . 现代空调, 2001, 3: 141~ 156.
[ 4] B W Olesen, E Michel. Heat Ex change Co efficient Between Floor Surface and Space by Floor Cooling- Theory or a Questionof Definition[ J] . ASHRAE Transactions: Symposia, DA- 00- 8- 2: 684~ 694.
[ 5] B W Olsen. Possibilities and Limitat ions of Radiant Floor Cooling [ J] . ASHRAE Transactions 1997( 103) , 1: 42~ 48.
[ 6] 1999 ASHRAE Applications Handbook, Chapter 52[ Z] .

Memo

Memo:
-
Last Update: 2013-04-29