|Table of Contents|

Influence of Adding the Insulation Board on Hot Short Circuit ofthe Vertical U-Tube Ground Heat Exchanger(PDF)

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

Issue:
2016年01期
Page:
66-
Research Field:
能源工程
Publishing date:

Info

Title:
Influence of Adding the Insulation Board on Hot Short Circuit ofthe Vertical U-Tube Ground Heat Exchanger
Author(s):
Luo LangYu YuejinZheng LipengXia Wen
School of Energy and Mechanical Engineering,Nanjing Normal University,Nanjing 210042,China
Keywords:
U-type buried tubeinsulation boardnumerical simulationheat exchange performance
PACS:
TK01+8
DOI:
-
Abstract:
The paper simulates with FLUENT software to build three -dimensional heat transfer model of U-tube buried tube heat exchanger. When adding insulation panels are simulated with and without conditions,to simulate the thermal circuit,the influence of the performance of ground heat exchanger is analyzed. By comparing the two kinds of working conditions of temperature and outlet temperature monitoring diagram,simulation proves that the hot short circuit phenomenon is serious between the two branch pipe,and after adding insulation board,the import and export temperature difference can reach 3.94 ℃,and the unit well depth in heat can be made to improve 6.13%.

References:

[1] 杨卫国,王京. 地源热泵系统热短路分析[J]. 建筑节能,2008,36(2):12-14.
YANG W G,WANG J. Thermal circuit analysis of ground source heat pump system[J]. Building energy-saving,2008,36(2):12-14.(in Chinese)
[2] 姚奇志,刘秋新,石文,等. 地源热泵地埋管热短路问题的研究[J]. 制冷与空调(四川),2012(6):536-540.
YAO Q Z,LIU Q X,SHI W,et al. Ground heat exchanger of ground source heat pump heat short-circuit problem[J]. Refrigeration and air conditioning(Sichuan),2012(6):536-540.(in Chinese)
[3] 吴金星,郭桂宏,李俊超,等. U型埋管换热器管间热短路性能数值分析[J]. 制冷与空调(四川),2014,(1):16-21.
WU J X,GUO G H,LI J C,et al. U-type buried tube heat exchanger tube numerical analysis of short-circuit characteristics[J]. Refrigeration and air conditioning(Sichuan),2014(1):16-21.(in Chinese)
[4] CENK Y,JEFFREY D S. Field validation of a short time step model for vertical ground-loop heat exchangers/Discussion[J]. Atlanta:a SHRAE transactions,2001(9):617.
[5] 杨正武,秦萍,刘宇,等. U型地埋管换热器热短路特性研究[J]. 制冷与空调(四川),2009,23(3):59-63.
YANG Z W,QING P,LIU Y. U-tube buried tube heat exchanger heat short-circuit characteristics[J]. Refrigeration and air conditioning(Sichuan),2009,23(3):59-63.(in Chinese)
[6] 沈国民,张虹. 竖直U型埋管地热换热器热短路现象的影响参数分析[J]. 太阳能学报,2007,28(6):604-607.
SHEN G M,ZHANG H. Vertical U-tube geothermal heat exchangers heat effect of a short circuit parameter analysis[J]. Journal of solar energy,2007,28(6):604-607.(in Chinese)

Memo

Memo:
-