|Table of Contents|

A Novel Method on the Sound Pressure Level EstimationApplied in Anechoic Chamber Calibration(PDF)

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

Issue:
2016年02期
Page:
10-
Research Field:
电气与电子工程
Publishing date:

Info

Title:
A Novel Method on the Sound Pressure Level EstimationApplied in Anechoic Chamber Calibration
Author(s):
Wang Qin1Yan Wei1Wang Enrong1Li Lin2Wu Yun2
(1.School of Electrical and Automation Engineering,Nanjing Normal University,Nanjing 210042,China)(2.Jiangsu Institute of Metrology,Nanjing 210023,China)
Keywords:
anechoic chambercalibration methodfree sound fieldair absorptionsound pressure level
PACS:
TB95
DOI:
10.3969/j.issn.1672-1292.2016.02.002
Abstract:
The formula to derivate sound pressure level based on the inverse law has some problems for the anechoic chamber calibration in JJF 1147 specifications,which causes the sound pressure level deviation to increase with the measurement distance from sound source closing. The influence of the air absorption factors have been analyzed on anechoic chamber calibration accuracy. A novel method is proposed to estimate the sound pressure level applied in the anechoic chamber calibration,which considers the air absorption attenuation and uses the nonlinear least square method to calibrate the theoretical sound pressure level. The present method can improve the calibration accuracy effectively and also provide the theoretical basis for the practical anechoic chamber calibration.

References:

[1] 国家质量监督检验检疫总局. 声学声压法测定噪声源声功率级消声室和半消声室精密法:GB/T 6882—2008[S]. 北京:中国标准出版社,2008.
AQSIQ. Acoustics-determination of sound power levels of noise sources-precision methods for anechoic and semi-anechoic rooms:GB/T 6882-2008[S]. Beijing:Standards Press of China,2008. (in Chinese)
[2] International standards organization. Acoustics-determination of sound power levels of noise sources using sound pressure-precision methods for anechoic and hemi-anechoic rooms:ISO 3745-2012[S]. Geneva:HIS,2012.
[3] 国家质量监督检验检疫总局. 消声室和半消声室声学特性校准规范:JJF 1147-2006[S]. 北京:中国计量出版社,2006.
AQSIQ. Calibration specification for acoustic performance of anechoic rooms and hemi-anechoic rooms:JJF 1147-2006[S]. Beijing:China Metrology Publishing House,2006. (in Chinese)
[4] 杨德俊,吴杰歆,何卓斌,等. 浅谈反平方律鉴定消声室自由声场的方法研究[J]. 家电科技,2012(4):76-78.
YANG D J,WU J X,HE Z B,et al. Preliminary discussion on method to calculate the sound pressure leve based on the inverse law in anechoic room[J]. Household appliance technology,2012(4):76-78. (in Chinese)
[5] 蒲志强,孙磊,鄂治群. 一种用于消声室校准计算反平方律声压级的新方法[J]. 计量学报,2013,34(5):466-468.
PU Z Q,SUN L,E Z Q. New method on estimation of sound pressure level based the inverse law in anechoic room calibration[J]. Acta metrologica sinica,2013,34(5):466-468. (in Chinese)
[6] 钟静,夏哲雷. 一种新的消声室声压级的计算方法[J]. 中国计量学院学报,2014,25(2):191-196.
ZHONG J,XIA Z L. A new method to calculate the sound pressure level of anechoic rooms[J]. Journal of China jiliang university,2014,25(2):191-196. (in Chinese)
[7] 国家质量监督检验检疫总局. 声学 户外声传播衰减 第1部分:大气声吸收的计算:GB/T 17247.1-2000[S]. 北京:中国标准出版社,2000.
AQSIQ. Acoustics-attenuation of sound during propagation outdoors-part 1:calculation of the absorption of sound by the atmosphere:GB/T 17247.1-2000[S]. Beijing:Standards Press of China,2008. (in Chinese)
[8] 高红武. 噪声控制技术[M]. 2版. 武汉:武汉理工大学出版社,2009.
Gao H W. Noise control technology[M]. 2nd ed. Wuhan:Wuhan University of Technology Press,2009. (in Chinese)

Memo