Experimental and Theoretical Study on the Influence of Pulse Power Supply on Electrostatic Precipitator Performance
Author(s):
Lu YangWang HongchengGu ZhongzhuXi JianfeiSong XianpingCai Jie
(School of Energy and Mechanical Engineering,Nanjing Normal University,Nanjing 210023,China)
Keywords:
cathode dischargedust removal efficiencyelectrostatic dust removalpulse power supply
PACS:
X513
DOI:
10.3969/j.issn.1672-1292.2022.03.003
Abstract:
Taking the dual-chamber five-electric field dry electrostatic precipitator system of a coal-burning power station 320 MW unit as the object,we test the characteristics of dust collection under 4 groups of different types of power conditions,and discuss the influence of pulse power on the dust removal performance. The influence of different types of power on the grading efficiency of dust collection each electric field are further analyzed. The result shows that the efficiency of the dust cleaning system tested can be more than 99.79% under four power operation conditions. The comparative tests show that pulse power supply can not only reduce energy consumption greatly,but also increase the removal efficiency of fine particles significantly. Especially,the difference of efficiency of dust collection is more significant with the dust particle size smaller. The dust particles are charged fully in the electric field of increased charging intensity with the rise of working voltage appropriately to improve the dust capture efficiency.

References:

[1]ZOUAGHI A,MEKHALDI A. Analysis of nanosecond pulsed and square AC dielectric barrier discharges in planar configuration:Application to electrostatic precipitation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2017,24(4):2314-2324.
[2]WANG J N,HUANG W J,XU H M,et al. Coagulation and capture offine particles in the coupling system of corona discharge and embedded turbulence[J]. Powder Technology,2021,382:85-94.
[3]GAO M X,ZHU Y,XIN Y,et al. Dust removal performance of two-stage electrostatic precipitators and its influencing factors[J]. Powder Technology,2019,348:13-23.
[4]邓艳梅.电除尘器的脉冲电源研究[D]. 武汉:华中科技大学,2017.
[5]ZHOU W N,JIANG R B,SUN Y F,et al. Study on multi-physicalfield characteristics of electrostatic precipitator with different collecting electrodes[J]. Powder Technology,2021,381:412-420.
[6]FIGUEROA-LARA J J,MURCIA-GONZÁLEZ J M,GARTÍNEZ R,et al. Effect of platform subway depth on the presence of airborne PM2.5,metals,and toxic organic species[J]. Journal of Hazardous Materials,2019,377:427-436.
[7]XIANG J B,WESCHLER C J,WANG Q Q,et al. Reducing indoor levels of “Outdoor PM2.5”in urban China:impact on mortalities[J]. Environmental Science & Technology,2019,53(6):3119-3127.
[8]RAÍSSA G S A A,VÁDILA G G. Discharge electrode influence on electrostatic precipitation of nanoparticles[J]. Powder Technology,2021,379:417-427.
[9]DU C,GONG X,LIN Y C. Decomposition of volatile organic compounds using corona discharge plasma technology[J]. Journal of the Air & Waste Management Association,2019,69(8):879-899.
[10]LUO Z Y,CHEN H,WANG T,et al. Agglomeration and capture of fine particles in the coupling effect of pulsed corona discharge and acoustic wave enhanced by spray droplets[J]. Powder Technology,2017,312:21-28.
[11]KIRK L M. Upgrading of electrostatic precipitators for sinter plants with pluse energization[M]. 北京:冶金工业出版社,2011.
[12]BECKERS F J C M,HOEBEN W F LM,HUISKAMP T,et al. Pulsed corona demonstrator for semi-industrial scale air purification[J]. IEEE Transactions on Plasma Science,2013,41(10):2920-2925.
[13]江建平. 细颗粒物脉冲荷电机理及凝并脱除方法研究[D]. 杭州:浙江大学,2015.
[14]张晓青,韩戈奇. 不同电控方式对电除尘器的提效特性及能耗分析[J]. 环境工程,2020,38(3):135-141.
[15]LAN Y,KE L,XIANG Z,et al. Nitric oxide removal from flue gas using dielectric barrier discharge coupled with negative pulse corona[J]. Chemical Engineering Research and Design,2019,143:170-179.
[16]SONG K,WANG H,JIAO Z,et al. Inactivation efficacy and mechanism of pulsed corona discharge plasma on virus in water[J]. Journal of Hazardous Materials,2022,422:126906.
[17]赵磊,周洪光. 近零排放机组不同湿式电除尘器除尘效果[J]. 动力工程学报,2016,36(1):53-58.
[18]王宏成. 基于高压脉冲电源阴极放电的静电除尘器除尘特性研究[D]. 南京:南京师范大学,2020.
[19]余旭平,代维敏,席剑飞,等. 线管式热电子发射高温静电除尘器的数值研究[J]. 南京师范大学学报(工程技术版),2017,17(2):42-48.
[20]张佳鹏. 线管式高温静电除尘特性实验研究[D]. 杭州:浙江大学,2013.
[21]张先鹏. 基于低逸出功阴极放电的静电强化颗粒层高温除尘器性能研究[D]. 南京:南京师范大学,2018.

Memo

Memo:
-
Last Update: 2022-09-15