Abstract:
This paper uses the constant heat flux method for thermal response test of single U and double U type buried pipe respectively which is based on ground source heat pump engineering project in Suzhou.Through this experiment,the geological condition of the project and the thermal physical parameters of rock and soil are obtained. At the same time,the performance of the ground heat exchanger under various operating conditions are calculated and analyzed.It is concluded that the average thermal conductivity of the soil in this area is 2.02 W/(m·K),and that the heat exchanger performance of double U pipes is about 15% higher than that of single U pipes.

References:

[1] LEE C,LAM H. Developing multiple regression models from the manufacturer’s ground-source heat pump catalogue data[J]. Renewable energy,2016(95):413-421.
[2]武曈,刘钰莹,董喆,等. 地源热泵的研究与应用现状[J]. 制冷技术,2014(4):71-75.
WU T,LIU Y Y,DONG Z,et al. The research and application of ground source heat pump[J]. Refrigeration technology,2014(4):71-75.(in Chinese)
[3]司子辉. 岩土热物性测试影响因素的研究[J]. 暖通空调,2014,(5):114-118.
SI Z H. Study on the influencing factors of thermal physical properties of rock and soil[J]. HVAC,2014(5):114-118.(in Chinese)
[4]孟庆龙,官燕玲. 土壤源热泵热响应测试研究进展及分析[J]. 西安建筑科技大学学报,2015(1):125-135.
MENG Q L,GUAN Y L. Research progress and analysis of thermal response test of soil source heat pump[J]. Journal of Xi’an university of architecture and technology,2015(1):125-135.(in Chinese)
[5]GB 50366—2005 地源热泵系统工程技术规范[S]. 北京:中国建筑工业出版社,2009.GB 50366-2005 Code for GSHP systems engineering technical[S]. Beijing:China Building Industry Press,2009.(in Chinese)
[6]陈海洋. 地源热泵U形竖直地埋管热响应试验及分析[J]. 暖通空调,2012(4):76-78.
CHEN H Y. Thermal response test and analysis of U-type vertical pipe of GSHP[J]. HVAC,2012(4):76-78.(in Chinese)
[7]张景欣,彭冬根. 基于线热源模型的垂直U型埋管换热器的换热分析[J]. 流体机械,2015(4):75-79.
ZHANG J X,PENG D G. Analysis of heat transfer of vertical U type heat exchanger based on line heat source model[J]. Fluid machinery,2015(4):75-79.(in Chinese)
[8]王华军,齐承英. 地下热响应实验中土壤初始温度的探讨[J]. 暖通空调,2010,40(1):95-98.
WANG H J,QI C Y. Discussion on the initial ground temperature during thermal response test[J]. HVAC,2010,40(1):95-98.(in Chinese)
[9]丁永昌,刁乃仁. 不同气候区岩土热物性测试分析[J]. 节能,2015(9):71-73.
DING Y C,DIAO N R. Test and analysis of thermal physical properties of rock and soil in different climatic zones[J]. Energy conservation,2015(9):71-73.(in Chinese)

Memo

Memo:
-
Last Update: 2016-12-31