[1]吴薇.水环热泵辅助热源性能研究[J].南京师范大学学报(工程技术版),2005,05(04):087-90.
 WU Wei.The Performance Studies on Auxiliary Heat Source of the Water Loop Heat Pump[J].Journal of Nanjing Normal University(Engineering and Technology),2005,05(04):087-90.
点击复制

水环热泵辅助热源性能研究
分享到:

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

卷:
05卷
期数:
2005年04期
页码:
087-90
栏目:
出版日期:
2005-12-30

文章信息/Info

Title:
The Performance Studies on Auxiliary Heat Source of the Water Loop Heat Pump
作者:
吴薇;
南京师范大学动力工程学院 江苏南京210042
Author(s):
WU Wei
School of Power Engineering,Nanjing Normal University,Jiangsu Nanjing 210042, China
关键词:
水环热泵 辅助热源 能耗
Keywords:
w ater loop heat pump aux iliary hea t source energy consum ption
分类号:
TB654
摘要:
介绍了水环热泵空调系统各种辅助热源的形式,针对传统水环热泵空调系统采用高位能(电、燃气、油、煤等)通过锅炉(或换热装置)转变为循环水的低位能,再由室内水/空气热泵提升后向室内供热的不合理的用能方式,提出了由空气源热泵代替锅炉的空气源—水环复合热泵空调系统,对其冬季建筑物内外分区不同的冷热负荷比下运行的性能进行了研究,并和使用锅炉的传统水环热泵空调系统的能耗进行了比较,体现出空气源水环复合热泵空调系统具有较高的能效比.
Abstract:
The form s o f d ifferen t aux iliary heat sources in the air condition ing system of wa ter loop hea t pump are introduced. A im ing at the irrationa l trad itional way o f supp ly ing hea t, in wh ich the h igh potentia l energy source ( e lectr ic ity, g as, o i,l coa,l etc) is changed into the low potentia l energy o f loop ing w ate r by bo iler ( o r heat transfe r insta llment ) and the looping w ater is heated by the indoorw ate r/ a ir source heat pum p and then supplies energy to indoor units, the paper proposes the a ir source-wa ter source hybrid heat pump system in w hich the bo iler is rep laced by air source heat pump, ca rr ies ou t the perfo rmance operated in the condition of d ifferen t co ld-and-ho t load ratio o f inside and outside bu ild ing d istr ict in w inter, and com pares it w ith the ene rgy consum ption o f trad itiona lw ater loop hea t pump in wh ich the bo iler was used. The results show tha t the energy e ffic iency ratio o f the a ir cond itioning sy stem o f air source-w ater source hybrid heat pum p is h igher.

参考文献/References:

[ 1] 马最良, 姚杨, 杨自强, 等. 水环热泵空调系统设计 [M ]. 北京: 化学工业出版社, 2005.
[ 2] 汪训昌. 水环热泵的热回收特性及其设计方法[ J]. 空调设计, 1997( 1) : 61- 72.
[ 3] Hughes P J. Survey o f w ater-source heat pum p system configurations in current practice [ J]. ASHRAE Trans, 1990, 12( 1): 1021- 1028.
[ 4] 汪训昌. 水环热泵(WLHP)系统及其热回收特性[ J]. 制冷与空调, 1997( 2): 12 -19.
[ 5] . 吴薇. 空气源-- 水源热泵复合热泵循环系统的性能研究[ D]. 南京: 东南大学, 2005.
[ 6] 谢汝镛. 我国水源热泵机组应用的现状与发展[ J]. 现代空调, 1999( 2) : 66- 77.
[ 7] 姜益强, 姚杨, 马最良. 外部低位热源与水环热泵空调系统[ C ] / / 全国热泵与空调技术交流会论文集. 宁波, [出版者不详], 2001: 111- 115.
[ 8] 吴业正, 韩宝琦. 制冷原理及设备[M ] . 西安: 西安交通大学出版社, 1997.

备注/Memo

备注/Memo:
作者简介: 吴  薇( 1974-) , 女, 讲师, 主要从事环境保护与能源利用的教学与研究. E-m ail: w uw ei@ n jnu. edu. cn
更新日期/Last Update: 2013-04-29