参考文献/References:
[1] 曹小林,曹双俊,段飞,等. 空气源热泵除霜问题研究现状与展望[J]. 流体机械,2011,39(4):75-77.
CAO X L,CAO S J,DUAN F,et al. Current situation and development prospect of air source heat pump defrosting research[J]. Fluid machinery,2011,39(4):75-77.(in Chinese)
[2]SANDERS C T. Frost formation:the influence of frost formation and defrosting on the performance of air coolers[D]. Nether lands:Delft University of Technology,1974.
[3]NIEDERER D H. Frost and defrosting effects on coil heat transfer[C]//ASHRAE,1976 Winter Conference. Texas:ASHRAE Transaction,1976.
[4]HOFFENBAKER N,KLEIN S A,RENDL D T. Hot gas defrost model development and validation[J]. International journal of refrigeration,2005,28(1):605-615.
[5]XIAO J,WANG W,ZHAO Y H,et al. An analysis of the feasibility and characteristics of photoelectric technique applied in defrost-control[J]. International journal of refrigeration,2009,32:1350-1357.
[6]许东晟,陈汝东. 除霜和除霜控制研究[J]. 流体机械,2006,34(1):69-73.
XU D S,CHEN R D. Study on defrost and defrosting control[J]. Fluid machinery,2006,34(1):69-73.(in Chinese)
[7]曾晓程,王俊,王铁军,等. 空气能热泵智能除霜技术研究[J]. 低温与超导,2017,45(12):91-94.
ZENG X C,WANG J,WANG T J,et al. Research on intelligent defrosting technique of air energy heat pump[J]. Cryogenics and superconductivity,2015,45(12):91-94.(in Chinese)
[8]郑福珍,刘健,王全福. 蒸发器除霜起点确定的理论与实验研究[J]. 应用能源技术,2013,12(12):45-48.
ZHENG F Z,LIU J,WANG Q F. In addition to theoretical and experimental study of frost point determined evaporator[J]. Applied energy technology,2013,12(12):45-48.(in Chinese)
[9]王伟,刘景东,孙育英,等. 空气源热泵两种新型高效除霜控制方法的实测研究[J]. 制冷与空调,2017,17(3):67-76.
WANG W,LIU J D,SUN Y Y,et al. Field test study of two types of the novel efficient defrosting control methods for air source heat pumps[J]. Refrigeration and air-conditioning,2017,17(3):67-76.(in Chinese)
[10]董云达,付兰. 空气源热泵机组除霜性能实验研究[J]. 制冷与空调,2007,7(2):68-71.
DONG Y D,FU L. Experiment on defrosting performance of air source heat pump units[J]. Refrigeration and air-conditioning,2007,7(2):68-71.(in Chinese)
[11]WANG Z Y,WANG X M,DONG Z M. Defrost improvement by heat pump refrigerant charge compen sating[J]. Applied energy,2008,85(11):1050-1059.
[12]石文星,李先庭,邵双全. 房间空调器热气旁通法除霜分析及实验研究[J]. 制冷学报,2000(2):29-35.
SHI W X,LI X T,SHAO S Q. Experimental research on hot vapor bypass defrosting method[J]. Journal of refrigeration,2000(2):29-35.(in Chinese)
[13]BYUN J S,LEE J H,JEON C D. Frost retardation of an air-source heat pump by the hot gas by pass method[J]. Int J refrigeration,2008,31(2):328-334.
[14]黄东,袁秀玲. 风冷热泵冷热水机组热气旁通除霜与逆循环除霜性能对比[J]. 西安交通大学学报,2006,40(5):539-543.
HUANG D,YUAN X L. Comparison of dynamic characteristics between the hot gas bypass defrosting method and reverse cycle defrosting method on an air to water heat pump[J]. Journal of Xi’an jiaotong university,2006,40(5):539-543.(in Chinese)
[15]孙福涛,蒲亮. 一种空气源热泵除霜新技术研究[J]. 制冷与空调,2017,17(4):7-10.
SUN F T,PU L. Research on a new defrosting technology applied to air-source heat pump[J]. Refrigeration and air conditioning,2017,17(4):7-10.(in Chinese)