[1]郝小充,余跃进,张宏,等.开式湖水源热泵系统温排水热扩散模拟研究[J].南京师范大学学报(工程技术版),2011,11(02):047-52.
 Hao Xiaochong,Yu Yuejin,Zhang Hong,et al.The Numerical Simulation of the Thermal Discharge in the Open-Loop Lake Water Heat Pump Systems[J].Journal of Nanjing Normal University(Engineering and Technology),2011,11(02):047-52.
点击复制

开式湖水源热泵系统温排水热扩散模拟研究
分享到:

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

卷:
11卷
期数:
2011年02期
页码:
047-52
栏目:
出版日期:
2011-04-09

文章信息/Info

Title:
The Numerical Simulation of the Thermal Discharge in the Open-Loop Lake Water Heat Pump Systems
作者:
郝小充1余跃进1张宏2翁雯1毛炳文1
( 1. 南京师范大学能源与机械工程学院,江苏南京210042; 2. 南京中兴软件有限责任公司,江苏南京210012)
Author(s):
Hao Xiaochong1Yu Yuejin1Zhang Hong2Weng Wen1Mao Bingwen1
1.School of Energy and Mechanical Engineering,Nanjing Normal University,Nanjing 210042,China;2.ZTE Software Co.,Ltd.,Nanjing 210012,China
关键词:
开式湖水源热泵排水位置温排水湖水深度数值模拟
Keywords:
open-loop lake water heat pumpdrainage positionthermal dischargelake water-depthnumerical simulation
分类号:
TU831
摘要:
针对南京某湖水源热泵项目,该方法利用标准k-ε紊流模型对热泵系统运行时温排水的热扩散进行了三维数值模拟.重点研究了深度不均湖体中,排水口位置对温排水热扩散效应的影响.通过分析比较得出,排水位置对水平方向温排水热扩散影响较大,而对垂直方向热扩散影响比较微弱,高温区集中于排水口附近的小区域;在允许范围内将取水口设置于排水口上游可以降低"热短路"造成的影响;在排水口附近采取喷水或跌水措施,可以降低热泵系统尾水造成的湖体环境温升,研究结果为开式湖水源热泵系统设计提供参考.
Abstract:
Combined the experience of a lake water heat pump project in Nanjing,based on the standard k - ε turbulence model,the temperature field of the thermal discharge into the lake water body was computed. The effect of the thermal diffusion caused by the different locations of the outfall was mainly researched when the lake-depth is uneven. By comparison and analysis,there is a greater influence as to the horizontal distribution than vertical direction,and the high temperature zone concentrates on a small area near the outfall,the short-circuiting can be avoided when the water intake is located on the upstream the outfall,the influence on-environment can be reduced with some measures such as sprinkler system and waterfall. The results provide reference for lake-water heat pump systems design.

参考文献/References:

[1]聂会元,吴艳菊,王勇. 中国气候区淡水源热泵适应性分析[J]. 重庆建筑大学学报, 2008, 30( 3) : 112-120. Nie Huiyuan,Wu Yanju,Wang Yong. Analysis of adaptability for water surface heat pumps in China climatic region[J]. Journal of Chongqing Jianzhu University, 2008, 30( 3) : 112-120. ( in Chinese)
[2]中国建筑工业出版社. GB50366 - 2005. 地源热泵工程技术规范[S]. 北京: 中国建筑工业出版社, 2009. China Architecture and Building Press. GB50366 - 2005. Technical code for ground-source heat pump system[S]. Beijing: China Architecture and Building Press, 2009. ( in Chinese)
[3]杨森,施明恒. 生态住宅自然能源利用系统的研究[J]. 南京师范大学学报: 工程技术版, 2001,1 ( 4) : 27-30. Yang Sen,Shi Mingheng. Research of natural energy using systems of ecological house[J]. Journal of Nanjing Normal University: Engineering and Technology Edition, 2001,1 ( 4) : 27-30. ( in Chinese)
[4]陈晓,张国强,彭建国,等. 开式地表水源热泵在湖南某人工湖的应用研究[J]. 制冷学报,2006, 27( 3) : 10-13. Chen Xiao,Zhang Guoqiang,Peng Jianguo,et al. Utilization of artificial lake as heat source-sink for open-loop surface water heat pump system in hunan[J]. Journal of Refrigeration, 2006, 27( 3) : 10-13. ( in Chinese)
[5]中国气象局气象信息中心气象资料室,清华大学建筑技术科学系. 中国建筑热环境分析专用气象数据集[M]. 北京: 中国建工出版社, 2005. The Meteorological Room of Meteorological Information Center of China Meteorological Administration,Building Science Department of Tsinghua University. Meteorological Data for Chinese Thermal Environment Analysis[M]. Beijing: China Architecture and Building Press, 2005. ( in Chinese)
[6]O. Buyukalaco. Experimental investigation of seyhan river and dam lake as heat source-sink for a heat pump[J]. Energy, 2003 ( 28) : 157-169.
[7]白振营. 一个计算湖泊( 水库) 自然水温的新公式[J]. 水文, 1999, 28( 3) : 29-32 Bai Zhenying. A new formula for calculating the water temperature of natural lakes ( reservoirs) [J]. Hydrology,1999, 28( 3) : 29-32. ( in Chinese)
[8]范亚明. 湖库塘开式水源热泵的水体传热与系统性能研究[D]. 重庆: 重庆大学城市建设与环境学院, 2009: 59-60. Fan Yaming. Study on thermal performance of lake and open-loop lake-source heat pump system[D]. Chongqing: Colledge of Urban Construction and Environmental Engineering,Chongqing University,2009: 59-60. ( in Chinese)
[9]黄向阳,吴拓. 湖水源热泵系统冷排水对湖泊水质的影响试验研究[J]. 水电能源科学,2009, 27( 6) : 34-37. Huang Xiangyang,Wu Tuo. Study on effects of cold discharge of lake water source heat pump systems on lake water quality [J]. Water Resources and Power, 2009, 27( 6) : 34-37. ( in Chinese)
[10]郝瑞霞,韩新生. 潮汐水域电厂温排水的水流和热传输准三维数值模拟[J]. 水利学报, 2004, 25( 8) : 66-70. Hao Ruixia,Han Xinsheng. Quasi 3 - D numerical model for flow and heat transport of power plant cooling water discharged into coastal area[J]. Journal of Hydraulic Engineering, 2004, 25( 8) : 66-70. ( in Chinese)
[11]王福军. 计算流体动力学分析- CFD 软件原理与应用[M]. 北京: 清华大学出版社, 2004. Wang Fujun. Computational Fluid Dynamics-Principle and Application of CFD Software[M]. Beijing: Tsinghua University Press, 2004. ( in Chinese)

备注/Memo

备注/Memo:
通讯联系人: 余跃进,教授,研究方向: 建筑节能. E-mail: dlkj@ njnu. edu. Cn