[1]严 磊,李文正,吴 薇,等.与热泵结合的预冷型溶液除湿空调系统性能研究[J].南京师范大学学报(工程技术版),2021,21(02):001-8.[doi:10.3969/j.issn.1672-1292.2021.02.001]
 Yan Lei,Li Wenzheng,Wu Wei,et al.Study on the Performance of Precooled Liquid Desiccant DehumidificationAir Conditioning System Combined with Heat Pump[J].Journal of Nanjing Normal University(Engineering and Technology),2021,21(02):001-8.[doi:10.3969/j.issn.1672-1292.2021.02.001]
点击复制

与热泵结合的预冷型溶液除湿空调系统性能研究
分享到:

南京师范大学学报(工程技术版)[ISSN:1006-6977/CN:61-1281/TN]

卷:
21卷
期数:
2021年02期
页码:
001-8
栏目:
动力工程及工程热物理
出版日期:
2021-06-30

文章信息/Info

Title:
Study on the Performance of Precooled Liquid Desiccant DehumidificationAir Conditioning System Combined with Heat Pump
文章编号:
1672-1292(2021)02-0001-08
作者:
严 磊李文正吴 薇何伊静郭辰雨张琪月廖扬颡
南京师范大学能源与机械工程学院,江苏 南京 210023
Author(s):
Yan LeiLi WenzhengWu WeiHe YijingGuo ChenyuZhang QiyueLiao Yangsang
School of Energy and Mechanical Engineering,Nanjing Normal University,Nanjing 210023,China
关键词:
溶液除湿冷凝热分配回风比冷冻水温
Keywords:
liquid desiccant dehumidificationcondensation heat distributionreturn air ratiofrozen water temperature
分类号:
TU834.9
DOI:
10.3969/j.issn.1672-1292.2021.02.001
文献标志码:
A
摘要:
提出一种与热泵结合的预冷型溶液除湿空调系统,利用室内回风作为再生空气、热泵冷凝热预热再生空气和再生溶液、冷冻水预冷除湿前溶液.建立了与实验数据具有良好吻合度的系统整体数学模型,模拟研究了系统再生侧热泵冷凝热分配比φ、再生空气回风比Rhf以及除湿侧冷冻水入口温度tw,in的变化对系统性能的影响. 结果表明,随着φ的增加,系统的再生能力除湿能力与性能系数均会下降. 随着Rhf增加,系统的除湿量和系统性能系数分别上升了30.95%和20.07%. 当tw,in升高时,再生侧的调节能抑制系统除湿能力的进一步下降. 研究结果为溶液除湿空调系统的优化提供思路.
Abstract:
A precooled solution dehumidification air conditioning system combined with a heat pump is proposed. The indoor return air is used as the regenerated air,the condensing heat pump is used to preheat the regenerated air and the regenerated solution,and the chilled water is used as the pre-cooled dehumidification solution. An overall mathematical model of the system is established,which is in good agreement with the experimental data. The effects of the cooling heat distribution ratio φ of the heat pump in the regeneration side,the return air ratio Rhf of the regenerated air and the inlet temperature tw,in of the chilled water in the dehumidification side on the system performance are simulated and studied. The results show that the regeneration capacity,dehumidification capacity and performance coefficient of the system decrease with the increase of φ. With the increase of Rhf,the dehumidification capacity and the system performance coefficient increase by 30.95% and 20.07%,respectively. When tw,in increases,the regulation on the regeneration side can inhibit the further decline of the dehumidification capacity. The research results provide ideas for the optimization of solution dehumidification air conditioning system.

参考文献/References:

[1] CHEN X J,RIFFAT S,BAI H Y,et al. Recent progress in liquid desiccant dehumidification and air-conditioning:a review[J]. Energy and Built Environment,2020,1(1):106-130.
[2]FEKADU G,SUBUDHI S. Renewable energy for liquid desiccants air conditioning system:a review[J]. Renewable and Sustainable Energy Reviews,2018,93:364-379.
[3]LI X,LIU S,TAN K K,et al. Dynamic modeling of a liquid desiccant dehumidifier.[J]. Applied Energy 2016,180:435-445.
[4]GURUBALAN A,MAIYA M P,GEOGHEGAN P J. A comprehensive review of liquid desiccant air conditioning system[J]. Applied Energy,2019,254:113673.
[5]KASHIF A,ALI M,SHEIKH N A,et al. Experimental analysis of a solar assisted desiccant-based space heating and humidification system for cold and dry climates[J]. Applied Thermal Engineering,2020,175:115371.
[6]LOWENSTEIN A. Review of liquid desiccant technology for HVAC applications[J]. HVAC&R Research,2008,14(6):819-839.
[7]ZHANG L,HIHARA E,SAIKAWA M. Combination of air-source heat pumps with liquid desiccant dehumidification of air[J]. Energy Conversion and Management,2012,57:107-116.
[8]CAI D H,QIU C B,ZHANG J Z,et al. Performance analysis of a novel heat pump type air conditioner coupled with a liquid dehumidification/humidification cycle[J]. Energy Conversion and Management,2017,148:1291-1305.
[9]LIU J,LIU X H,ZHANG T. Performance of heat pump driven internally cooled liquid desiccant dehumidification system[J]. Energy Conversion and Management,2020,205:112447.
[10]CHEN Y,YIN Y G,ZHANG X S. Performance analysis of a hybrid air-conditioning system dehumidified by liquid desiccant with low temperature and low concentration[J]. Energy and Buildings,2014,77:91-102.
[11]NIU X,XIAO F,MA Z J. Investigation on capacity matching in liquid desiccant and heat pump hybrid.[J]. International Journal of Refrigeration,2012,35(1):160-170.
[12]张凡,吴薇,张甜湉,等. 一种冷凝热分级利用复合型溶液除湿空调系统性能分析[J]. 南京师范大学学报(工程技术版),2014,14(3):33-42.
[13]OU X H,CAI W J,HE X X. et al. Experimental investigations on heat and mass transfer performances of a liquid desiccant cooling and dehumidification system[J]. Applied Energy,2018,220:164-175.
[14]ZHANG L Z,ZHANG N. A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system:modeling and experimental validation[J]. Energy,2014,65:441-451.
[15]邹同华,张涛,马淑媛,等. 溶液除湿系统除湿性能实验研究[J]. 暖通空调,2013,43(1):76-79.
[16]刘晓华. 溶液调湿式空气处理过程中热湿耦合传递特性分析[D]. 北京:清华大学,2007.
[17]LIU J,LIU X H,ZHANG T. Performance comparison of three typical types of internally-cooled liquid desiccant dehumidifiers[J]. Building and Environment,2016,103:134-145.
[18]ZHANG T,LIU X H,JIANG J J. Experimental analysis of an internally-cooled liquid desiccant dehumidifier[J]. Building and Environment,2013,63:1-10.
[19]SHAN N,YIN Y,ZHANG X. Study on performance of a novel energy-efficient heat pump system using liquid desiccant[J]. Applied Energy,2018,219:325-337.
[20]ZHANG T,LIU X H,JIANG Y. Performance optimization of heat pump driven liquid desiccant dehumidification systems[J]. Energy and Building,2012,52:132-144.
[21]ZHANG F,YIN Y,ZHANG X. Performance analysis of a novel liquid desiccant evaporative cooling fresh air conditioning system with solution recirculation[J]. Building and Environment,2017,117:218-229.
[22]WANG X L,CAI W J,LU J G,et al. Model-based optimization strategy of chiller driven liquid desiccant dehumidifier with genetic algorithm[J]. Energy,2015,82:939-948.

相似文献/References:

[1]张 凡,吴 薇,张甜湉,等.一种冷凝热分级利用复合型溶液除湿空调系统性能分析[J].南京师范大学学报(工程技术版),2014,14(03):033.
 Zhang Fan,Wu Wei,Zhang Tiantian,et al.Performance Analysis of a Hybrid Liquid Desiccant Air-ConditioningSystem with Sectional Utilization of Condensation Heat[J].Journal of Nanjing Normal University(Engineering and Technology),2014,14(02):033.

备注/Memo

备注/Memo:
收稿日期:2020-12-07.
通讯作者:吴薇,副教授,研究方向:制冷与节能技术研究. E-mail:wuwei@njnu.edu.cn
更新日期/Last Update: 2021-06-30